1、Basic Infomation
◆ Place of Origin: CN
◆ Brand Name: Eltek
◆ Certification: CE
◆ Model Number: 241115.705
2、Payment & Shipping Terms
◆ Packaging Details: cartons
◆ Delivery Time: 8-10 weeks
◆ Payment Terms: L/C, T/T
◆ Supply Ability: 3000 pieces per month
3、Product Description
Ready to Ship Eltek 48V 60V Converter FP2 Rectifier Module Flatpack 2 48-60/2000he P/N 241115.705
The most efficient power conversion module in the industry! Since the launch the Flatpack 2 family has expanded intoa wide selection of power ratings and voltages.
Model 48-60/2000 HE Part number 241115.705 INPUT DATA Voltage (nominal) 185 - 275 VAC / 185 - 275 VDC Voltage (operating range) 85 - 300 VAC / 80 - 300 VDC Current (maximum) @ nominal input, full load 11.6 ARMS Frequency 45 - 66 Hz / 0 Hz Power Factor > 0.99 at 50% load or more THD < 5% at 100% load Protection Fuse in L & N, Varistor, Shutdown when input voltage is out of operating range OUTPUT DATA Voltage (default) 1) 53.5 VDC (67 VDC in 60V mode) Voltage (adjustable range) 1) 39.9 - 72 VDC Power (maximum) @ nominal input 2000 W (@VOUT ≥ 48VDC) Power @ 85 VAC 750 W Current (maximum) @ nominal input 41.6 A (@VOUT < 48VDC) Hold up time, 1500W output power >20ms; output voltage > 53.5 VDC (60V mode) Current sharing (10 - 100% load) ±5% of maximum current from 10 to 100% load Static Voltage regulation (10 - 100% load) ±0.5% Dynamic Voltage regulation ±5.0% for 10-80% or 80-10% load variation, regulation time < 50ms Ripple & noise < 150 mVPP , 30 MHz bandwidth / < 2 mVRMS psophometric Protection Fuse , Short circuit proof, High temperature protection, Over voltage Shutdown OTHER SPECIFICATIONS Efficiency 96.2 % Isolation 3.0 kVAC - input to output, 1.5 kVAC - input to earth, 500 VDC - output to earth Low / high input voltage shutdown, High / low temperature shutdown, Rectifier
Alarms: Red LED Failure, Overvoltage shutdown on output, Fan failure, Low output voltage alarm, CAN bus failure
Rectifier in power de-rate mode, Remote output current limit activated, Input
Warnings: Yellow LED voltage out of range, flashing at overvoltage, Loss of CAN communication with
controller
Normal operation: Green LED MTBF (Telcordia SR-332 Iss.I method III (a)) >350 000 (@ Tambient : 25 °C) Operating temp. (5-95% RH n.cond. hum.) -40 to + 75°C [-40 to +167°F] Max output power de-rates above temp / to 45°C [113°F] / 1200W @ 75°C[167°F] Storage temperature -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing Dimensions[WxHxD] / Weight 109 x 41.5 x 327mm (4.25 x 1.69 x 13”) / 1.950 kg (4.3lbs) DESIGN STANDARDS Electrical safety EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013, IEC 60950-1:2013 UL 60950-1:2011 EMC EN 61000-6-1:2007, -6-2:2005, -6-3:2007 + A1:2011, -6-4:2007 + A1:2011,
IEC 61000-6-5: 2015, ETSI EN 300 386:2.1.1
Marine DNVGL-CG-03392) ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3)
Environment 2011/65/EU (RoHS) & 2012/19/EU (WEEE)Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other
operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised
1) OVS setting from controller select mode: OVS≤59.5V = 48V mode (42-58V), 59.5V<OVS<70.85 = 48V NiCad mode (39.9-66V) and OVS≥70.85V = 60V mode (52.5-72V). When de-energized module will return to 48V mode.
2) Only valid for part number 241115.705M
Key features
◆ Super High Efficiency – up to 97.8%
◆ High power density – 33 w/in3
◆ Compatible with existing systems
◆ Global compliance
◆ Patented technology
◆ Hot pluggable
4、Product Display
Eltek 48V 60V Converter FP2 Rectifier Module Flatpack 2 48-60/2000he P/N 241115.705
◆ Model Name: Flatpack2 48=60V/2000HE
◆ Application: Telecom Power Core Systems
◆ Output Voltage: 60Vdc
◆ Frequency: 50/60HZ
◆ Part No.: 241115.705
◆ Effciency: 97.8%
◆ Input Voltage: 220Vac
◆ Nominal: 53.5Vdc
◆ Weight: 2.1 Kg
◆ High Light: flatpack2 2000w 48v, Eltek rectifier module